Rail-Switch II Specification
Mechanical
Housing: DIN Rail Case
y
Material: Polycarbonate plastic, UL94-V0
y
rated
Overall dimensions: 90 mm (H) x 88 mm
y
(W) x 62 mm (D)
Weight: 0.2 kg
y
Mounting: 35 mm DIN Rail or Surface
y
Mount
Country of manufacture: UK
y
Environmental
Operating temperature: 0°C to 40°C
y
Storage temperature: -10°C to +50°C
y
Operating relative humidity (max): 80%
y
non-condensing
IP rating: IP20 indoor use only
y
Certification: CE, WEEE, RoHS
y
Warranty: 2-year (return to base)
y
Power & Electrical
Input voltage: 9-24 VDC
y
Input connector: 2-pin pluggable screw
y
terminal (1 no.)
Input power (max): 10 W
y
Duty cycle: 100% @ 25°C
y
DC fuse: internal resettable fuse for
y
control electronics
DMX512 input
Input mode: Non-isolated
y
Input ESD protection: 12 kV
y
Input voltage protection: +/- 80 V
y
Rail-Switch II User Guide
Outputs
Type: 6 x changeover relay, volt-free
y
contacts
Connectors: 3-pin screw terminals (6 no.)
y
Maximum switching voltage: 250 VAC
y
Maximum peak current: 8A
y
Rated load (AC1 non-inductive): 2,000 VA
y
Rated load (AC15 inductive): 500 VA
y
Rated load (Single phase motor): 0.37 kW
y
Minimum load: 500mW
y
Protection:
User
y
protection
Isolation: 1 kV between relay contacts
y
Control
Input Protocols: DMX512, DMX512(1990),
y
DMX512-A
RDM V1.0 (E1.20 - 2006 ESTA Standard)
y
Data Connection
3-pin Screw Terminal DMX Input (1 no.)
y
4-pin Screw Terminal DMX Loop / Term
y
(1 no.)
LED Indication
Power / DMX / RDM / Preset / Test / RDM
y
locate / Relay
Configuration
Commissioner, DMX Workshop
y
Configurable settings include:
y
-
Start address (individual for each relay)
-
Preset, data loss and test modes
Package Contents
Rail-Switch II
y
User guide
y
Ordering Info
Product code: Rail-Switch II
y
Accessories (not included)
PSU-24-2-DR
y
supplied