DKM Motor GEARHEAD Benutzerhandbuch - Seite 18
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Motor DKM Motor GEARHEAD herunter. DKM Motor GEARHEAD 20 Seiten.
![DKM Motor GEARHEAD Benutzerhandbuch](/uploads/products/server2/867964/867964.jpg)
In case of abnormal operation of motor and gearhead, please
refer to below table and make inspection. If motor doesn't
operate normally even inspection result is normality even after
checking, do not repair voluntarily or disassemble motor but
contact DKM head office or local agent. Please be noted that
for the problem caused by user's voluntary repair of disassembly,
DKM doesn't take responsibility and A/S may be impossible.
PHENOMENON
Output shaft does not
rotate or runs slow.
Sounds abnormal noise
Output shaft stops
suddenly.
15
CHECKING POINT
1) Is proper voltage applied to the motor?
2) Are lead wires connected correctly?
3) Is the load too large?
4) Is capacitor connected as diagram
and same value as written on label?
1) Are motor and gearhead mounted
correctly?
2) Did you use same type of gearhead
shaft as motor shaft?
1) Is the motor TP(Thermal Protector) type?
2) Did transmission components get
damaged or did not connect properly?
3) Does motor or gearhead end the life
expectation?
4) Does output shaft break down?
5) Gears can get damaged if only motor
runs. (If so, it may over loaded, please
check permissible torque refer to '3.3
Permissible Torque of Gearhead.)
5. Troubleshooting