DKS 1600 Series Benutzerhandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Toröffner DKS 1600 Series herunter. DKS 1600 Series 19 Seiten. Vehicular gate operators with battery backup
1.3 TERMINAL DESCRIPTION
1.
COMMON
Common terminal for open input and radio receiver connected to the backup board.
Note: Radio receiver cannot be connected when the system is installed in a
1601 or 1602 barrier gate operator.
2.
OPEN INPUT
Input from push button or radio receiver (slide and swing operators only) will activate
the gate operator.
3.
RADIO POWER
24 -Volt power for radio receiver (slide and swing gate operators only).
4.
ACTIVATION OUTPUT
Radio relay activation or switch closure across terminals 1 and 2 will send an
activation signal out of this terminal to the gate operator single-button activation input.
5.
24 VAC INPUT
6.
24 VAC COMMON
7.
BATTERY POSITIVE INPUT
8.
BATTERY NEGATIVE INPUT
9.
DC MOTOR POSITIVE OUTPUT
10.
DC MOTOR NEGATIVE OUTPUT
1
2
3
4
5
6
7
8
9
10
Page 7
FACTORY
ADJUSTMENT ONLY!
MOTOR
RUN
INCREASE
FACTORY
ADJUSTMENT ONLY!
CHARGE
Led
2340-010