QUICKSTART "BASIC" GUIDELINES FOR MODEL 6300 - DIP-SWITCH AND WIRING REFERENCE
SW 1 DIP-Switches
Switch
Function
Setting
Relay activates when gate is open (Shadow loop setting when used).
1-OFF
2-OFF
Circuit
Relay activates when gate is not closed.
1-OFF
2-ON
1 and 2
Board
Relay activates when gate is opening and open.
1-ON
2-OFF
Relay
Relay activates when gate is opening and closing.
1-ON
2-ON
Exit Loop Port
The output wired to terminal #12 becomes the output from the exit loop detector
OFF
3
Output
plugged into the EXIT Loop port.
Full Open Input
ON
Normal Setting. Terminal #12 is a normal full open input.
Auto-close timer is OFF. Manual input required to close gate.
OFF
Auto-Close
4
Timer
Auto-close timer is ON. Adjustable from 1-23 seconds to close gate.
ON
Slide Gate
OFF for Slide gate operator (DO NOT use for 6300).
OFF
5
Swing Gate
ON
Normal Setting. ON for Swing gate operator (Switch MUST be ON for 6300).
3-Button
OFF
OFF when using a 3-button station (DoorKing 3-button control stations only).
SW 1
6
Single Button
ON when using a single button control, terminals 13 &14 become a STOP input.
ON
Dual Operators
Switch must be OFF when bi-parting (dual) gates are used.
OFF
7
Single Operator
Switch must be ON for single operator.
ON
OFF
Tamper protect is OFF.
8
Tamper Protect
ON
Normal Setting. Tamper protect is ON.
SW 2 DIP-Switches
Switch
Function
Setting
Primary 6300
Opens
Changes Gate
Clockwise
1
Opening
Direction
Secondary 6300
Changes Gate
2
Opening
Direction
Normal Setting. Normal operation.
OFF
3
Self-Test
Self-test mode. Operator MUST be disconnected from gate to run self test.
ON
Switch is OFF when both primary and secondary operator motors are powered
OFF
from main terminals 4 and 5. Applies to operators originally manufactured with
Motor Control
4501, Rev O boards or lower).
SW 2
4
for Secondary
Switch is ON when secondary operator motor is powered from the secondary
Operator
ON
motor terminals. Applies to operators manufactured with 4501, Rev P boards and
higher, and all 4502 boards.
Terminal 15 is a normal Reverse input.
Reverse Loop
OFF
5
Shadow Loop
ON
Terminal 15 is a Shadow input. Gate will NOT stop during the close cycle.
OFF
Primary and secondary operators start at the same time.
6
Gate Overlap
ON
Secondary operator starts 1-2 seconds prior to primary operator.
7
Not Used
Leave in the OFF position.
OFF
8
Not Used
OFF
Leave in the OFF position.
Every time the operator is powered up, the First open command
will automatically set the open and close limits of the gate.
Description
Description
Opens
Counter-Clockwise
ON
OFF
Same as above, for secondary 6300 ONLY.
Model 6300 is intended for installation only on swing gates used for vehicles.
Pedestrians must be supplied with a separate access opening.
For safety and installation instructions, please refer to the Installation/Owner's manual.
Important:
Controls must be installed a minimum
of 10-feet from the gate or installed in such a way
that the person using the control cannot come in
contact with the gate or gate operator.
#11 - Access Control
Devices
Telephone
Entry
Key Switch
Stand-Alone
Keypad
Stand-Alone
Card Reader
Magnetic Lock
Note: All stand-alone and
telephone entry devices must
Power (24 Volt DC) and
use a separate power source.
logic output. Power is
shut off .5 sec. prior to
gate starting and remains
off while gate is opening
#12 - Safety
and in the open position.
Opening Device
Com
Com
SW 1
SW 1, switch 3 must be ON.
Antenna mounted
outside operator cover.
(2) Two 115 VAC
Convenience Outlets
Coax Antenna Kit
P/N 1514-073
3-Wire Radio Receiver
Limited to 250 ma.
Convenience Open Radio
Receiver Note:
Wiring may differ.
See section 7 in the
Installation/Owner's
manual for more info.
1
2
3
3-Button Station
Red Open
4
Green Close
5
White Com
6
DoorKing ONLY
7
8
9
10
11
12
13
14
15
16
17
24 Volt
18
1 amp max.
19
20
120 Glasgow Avenue
Inglewood, California 90301
U.S.A.
Radio
Open
Access
Device
Open
Safety
Open
SW 1
NC
NO
SW 2
Com
Com