dlb AIJGO-22LCD Gebrauchsanweisung - Seite 4
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Prüfgeräte dlb AIJGO-22LCD herunter. dlb AIJGO-22LCD 16 Seiten. Personal grounding tester with lcd display and dual foot electrode
Resistance values indicated as acceptable by the tester
Default setting when measuring footwear system
An upper value of 100 MΩ can be set using the red switch at the bottom of the tester. However, after setting a different
limit from the one used previously, the device must be restarted for the change to take effect.
Default setting when measuring wrist strap/
groundable ESD smock system
Test voltage
Wrist strap/groundable ESD smock system
connection:
Power supply
Relay outputs
Sizes
TECHNICAL INFORMATIONS
100 KΩ – 35 MΩ
750 KΩ – 35 MΩ
100 V DC
With a combined 10 mm snap, 4 mm banana
plug socket
12 V DC
0,5 A/60 V
Pass relay (Normally Open) with green wire
Fail relay (Normally Open) with red wire
215 x 195 x 55 mm (tester)
500 x 630 x 970 mm (tester+stand with dual
foot electrode, assembled), the touch button
emerges from it beyond this, the tester extends
14 cm backwards beyond the platform. The
size of the platform itself (for tester version with
stand): 500 x 490 x 20 mm.
Tilt angle of the stand: 5 degrees
4