9.6 Attaching the End terminals

Potential Hazards:
Injury from movements and
posture, hand injury from pinch points, strain to wrists
from tightening bolts and excessive noise from use of
impact driver.
Recommended Control Measures:
techniques (bend at the knees), wear gloves, use a
pinch bar to align holes, use an impact wrench to
tighten bolts and wear appropriate hearing protection.
Attach the RiderPro end terminal () to the beam
using four M16 x 35 mm guardrail bolts (), standard
nuts and round washers.
The End terminal must overlap the beam so that the
splice is with the flow of traffic.
Place the end post bracket () at the last/first
guardrail post and fix it by means of two M16x110 mm
Hex Head Blots (), standard nuts and round washers,
but do not fully tighten them for the moment.
Align the 18 mm wide slots of the end post bracket with
the 18 x 50 mm centered slots of the RiderPro beam
and attach them with two M16 x 35 mm guardrail bolts
() standard nuts and round washers.
3
4
Figure 5. Termination of RiderPro attached to
the ACP Sentry Barrier
Ref: IM 031 Rev 00
Date: 15/07/2021
Page 10/17
Observe correct
5
1
2
Beam System.
Before tightening the bolts ref.
attention to adjust the ground clearance of the beam
(see § 9.7).
9.7

Adjusting the ground clearance

Prior to tightening the bolts that connect the RiderPro
beams to the brackets, it is recommended to adjust
the height of the bottom of the beams from the
ground, according to the installation clearance (30
mm) in Figure 6. At this point it may be necessary to
loosen the M10x25 bolt used to RiderPro mounting
bracket to the Sentry Post to achieve the appropriate
installation clearance. Should that be necessary it is
require to reapply the recommended 40 to 80 inch-
pounds (4.5 to 9.0 Nm) of torque.
Recommended Control Measures:
impact wrench to tighten bolts and wear appropriate
hearing protection.
Figure 6. ACP Sentry Barrier: RiderPro Ground clearance.
The adjustment completed, bolts connecting the
beams to the brackets can now be tightened forming a
snug connection (there is not a specific torque value
required).
The finished position of the RiderPro beam should be
parallel to the beam guardrail and to the ground.
and
too snug, pay
wear gloves, use an
Property of
Margaritelli Ferroviaria S.p.A.
06135 Ponte San Giovanni - Italy