ET Solar ET-P660 series Installationshandbuch - Seite 7
Blättern Sie online oder laden Sie pdf Installationshandbuch für Sonnenkollektor ET Solar ET-P660 series herunter. ET Solar ET-P660 series 10 Seiten.
- 1. 1 Company Introduction
- 2. 2 Structure of Module
- 2. Table of Contents
- 2. Installation
- 3. 3 Installation of Modules
- 3. Mounting with Bolts
- 3. Mounting with Clamps
- 3. Anti-Salt Module Mounting Procedure
- 3. Grounding of Normal Modules
- 3. Fire Safety
- 3. Junction Box
- 3. Output Voltage, Current and Maximum Power
- 4. 4 Characteristics of Modules
- 5. 5 Operation and Maintenance
- 6. 6 Disclaimer of Liability
- 7. Appendix 1:Electrical Ratings of ET Solar Modules
Use components such as ground fault circuit breakers and fuses as required by local
authority.Do not use panels near equipment or in places where flammable gases may be
generated.
The modules have been rated Fire Class C, and are suitable for mounting on to a Class A
roof. The module fire performance is type 1 rated with the special construction in below
table.
Module Model
Specific Construction
Superstrate:
3.2mm≤thickness≤4.36mm;
Encapsulant:
0.25mm≤thickness≤thickness of
All Models
Item 2b in 4.0;
Substrate: thickness of item 15f
in 4.0≤thickness≤0.64mm
Confirm mounting slope less than 5 in/ft (127mm/305mm) to maintain a fire class rating.
Be aware of the linear thermal expansion of the module frames (the recommended
minimum distance between two modules is 1 cm).
3.3 Junction box
The junction box should be fixed on the top end of the module during installation so as to
prevent the seepage of rain.
ET Solar provides a wiring type box. When the integrated J-box is adopted, no tool is
necessary for wiring. Just connect the modules in series according to "+" or "-" . You can
complete complex series and parallel connection easily and quickly using different
electric connectors provided by your supplier.
10
www.etsolar.com
Subject to technical modifications without notice. 2016 © ET Solar Group
Connectors provided by different suppliers will not mutually match up.Different
connectors provided by one supplier will not match up either.Only one type of the same
connector from one supplier should be used to ensure the reliability of the electrical
connection.
Module Type
Type 1
www.etsolar.com
Male
Female
Module
connector
connector
1394461-2
1394462-4
PV-KST4
PV-KBT4
ET-P654 series
TL-Cable01M
TL-Cable01F
ET-P648 series
QC4.10
QC4.10
ET-P636 series
H4
PV-JM601M
PV-JM601F
A6-2
1394461-2
1394462-4
PV-KST4
PV-KBT4
ET-P672series
TL-Cable01M
TL-Cable01F
ET-P660 series
QC4.10
QC4.10
ET-M660 series
H4
ET-M672 series
PV-JM601M
PV-JM601F
A6-2
SL4-11(Male)
SL4-11(Female)
PV-KST3
PV-KBT3
ET-M572 series
TL-Cable01M
TL-Cable01F
ET-M536 series
QC4.10
QC4.10
H4
Subject to technical modifications without notice. 2016 © ET Solar Group
www.etsolar.com
Manufacturer
Notes
Tyco Electronics
Multi-Contact
Zhenjiang Tongling
12AWG
QC Solar
wire
H4
Amphenol
Zhejiang Jaming
A6-3
T-Conn Precision
Tyco Electronics
Multi-Contact
Zhenjiang Tongling
QC Solar
12AWG
H4
Amphenol
wire
Zhejiang Jaming
A6-3
T-Conn Precision
Dongguan Zerun
Multi-Contact USA
Zhenjiang Tongling
12AWG
QC Solar
wire
H4
Amphenol
11