fleetfinder GOLD Benutzerhandbuch - Seite 10

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für GPS fleetfinder GOLD herunter. fleetfinder GOLD 19 Seiten.

Fleetfinder GOLD
Command
SETGPO N L
Sets the outputs N for Latch
SETGPO N P
Sets the output N for Pulse.
SETGPO N C
Sets the output N for Cycle.
LABELGPO N
Renames the label heading for an
output
QUERYOUTLABEL N
Queries the Label settings for the
Outputs.
GPO N ON
Enables/Disables outputs where N
is the input number
GPO N OFF
Enables/Disables outputs where N
is the input number
SPEED KKK
To notify the primary identity when
the Speed limit is exceeded.
STATUS
Reports back with the features that
are enabled on the Fleetminder.
SYS
Reports back additional unit param-
eters, including the Voltage, GPS
and GSM signal strength etc.
Purpose
Default setting
This is default setting
No default
No default
No default
Default setting is all outputs
switched off.
Default setting is all outputs
switched off.
Default is off
No default
No default
Options
SETGPO 1 L - Will set output 1
SETGPO 1 L - Will set output 1
for Latch
for Latch
SETGPO 1 P - Will set output 1
SETGPO 1 L - Will set output 1
for Pulse
for Pulse
SETGPO 1 C - Will set output 1
SETGPO 1 C - Will set output 1
for Cycle
for Cycle
Up to 16 characters for all 7outputs.
LABELGPO 1 Siren will set the label
LABELGPO N where N is the
of output 1 to "Siren"
number of the output
QUERYOUTLABEL N where N is
QUERYOUTLABEL 1 will request
the input number (input 1 to 7)
the LABEL heading for Output 1
GPO 1 ON - Will trigger output 1 to
switch on.
GPO 1 OFF - Will trigger output 1
to switch off.
SPEED KKK where KKK is the
SPEED 65 will trigger when the
speed in Kmh. SPEED 00 disables
speed of vehicle goes over 65kmh.
Speed alerts.
P15
Example
SMS Response.
(Queried Via SMS).
CFG:SETGPO N L (where N is the
number of the input and L is the
Latch setting)
CFG:SETGPO N P (where P is the
number of the input and P is the
Pulse setting)
CFG:SETGPO N C (where N is the
number of the input and C is the
Cycle setting)
CFG:LABELGPO N X (where n is
the input number and x is the input
name)
CFG:QUERYOUTLABEL N X
(where n is the number of the
output, and x is the label that is ser
for the output queried)
CFG:GPO N [GPOLABEL] ON
(where N is the ouput number)
CFG:GPO N [GPOLABEL] OFF
(where N is the output number)
CFG:SPEED X (where X is the
speed in Kmh)
[UNIT ID],speed x,battery x%,ip
x,port x,tow O,AD,GPO N O (where
[unit id] is the unit ID, X is a number,
AD is the AD setting (temperature or
analogue), N is the output number,
and O is the output status)
[UNIT ID],Firmware V,GSM signal
x%,GPS Status O,GPRS O,Voltage
x% (where [UNIT ID] is the unit
ID, V is the firmware version, x is
a number value, and O is status
ON /OFF)