Mounting the housing connectors
-
mount the housing connector using the locknuts and
tighten them f irmly
Flat roof installation
see installation instructions for collector mountings -
f ree-standing (Art. no. 20070), f ree standing 10° (art. no. 20275)
Facade installation
see installation instructions for collector attachments - attachment set for facade
(art. no. 20285)
Pitched roof installation
see installation instructions for collector attachments - on-roof tile (art. no. 20084),
on-roof slate (art. no. 20200)
Observe the angle of the collectors
For a system for domestic water heating, we recommend the absorber
align 45° to the sun. With the combination of service water heating & heating
we recommend aligning the absorber at 60° to the sun.
Observe the operating pressure
The operating pressure (min. operating pressure) of the system P should be set in the cold
state (20°C) so that a pressure of 1.5 bar results at the level of the collectors (headers).
Example:
The collector was installed at a height of 10 m above the membrane expansion vessel
(MAG). expansion vessel (MAG). P = (h x 0.1) + 1.5 bar, P = (10 x 0.1) + 1.5 bar corresponds to
P = 2.5 bar. The inlet pressure of the MAG should be set 0.3 - 0.5 below the system pressure
P in the depressurized state.
This is only a rough guide. Please use the easy system planner for the design, which you
can download at www.akotec.eu.