Clinton Electronics CE-M21A-PIR Handbuch zur Grundeinstellung - Seite 6

Blättern Sie online oder laden Sie pdf Handbuch zur Grundeinstellung für Digitalkamera Clinton Electronics CE-M21A-PIR herunter. Clinton Electronics CE-M21A-PIR 9 Seiten. Pvms w/ axis m3065
Auch für Clinton Electronics CE-M21A-PIR: Handbuch zur Grundeinstellung (7 seiten)

Clinton Electronics CE-M21A-PIR Handbuch zur Grundeinstellung
Resetting the AXIS M3065 Camera 10" models
Reset to factory default should be used with caution. A reset to factory default will reset all camera settings,
including the IP address, to the factory default values.
Remove 2 screws
on back of PVM
Disconnect power from the PVM.
1
To access the camera, remove the 2 door screws located on the back of the PVM. Keep these screws in a safe
2
place to close the access plate when fi nished.
Press and hold the control button and reconnect power. The control button is partially behind the cover plate
3
opening— nearest the camera. (keep holding the control button down while reconnecting power)
Continue holding the control button until the LED on the camera board starts fl ashing Green/Red. (approx
4
15-30 seconds). *The LED is partially hidden under the cover plate opening. Release the button then close and
secure the camera access plate.
Color bars will be displayed during the reset. If using the fi rmware that shipped with the camera, the
camera image will return once the reset has fi nished and no additional setup is required. See next page
if the camera fi rmware has been updated.
Basic Setup Guide: "A-Series" PVMs w/ AXIS 3065 Camera
11.21.22
Press/Hold Control Button
(Slightly behind cover plate)
Information in this document is subject to change without notice.