Resetting the AXIS M3045 Camera
Reset to factory default should be used with caution. A reset to factory default will reset all camera settings,
including the IP address, to the factory default values. After camera reset, additional steps are needed to display
the camera image on the screen.
Remove 2 screws
on bottom of PVM
Disconnect power from the PVM.
1
To access the camera, remove the 2 door screws located on the bottom of the PVM. Keep these screws in a safe
2
place to close the access door when finished.
Press and hold the control button and reconnect power. The control button is nearest the camera. (keep
3
holding the control button down while reconnecting power)
Continue holding the control button until the LED on the camera board starts flashing Green/Red. (approx 15-
4
30 seconds). Release the button then close and secure the camera access door.
The camera image will not be displayed on the screen after a reset. Color bars will be displayed. Login
to the camera and make the following adjustments to restore the camera image.