5.4.0 ****** MISCELEN
5.4.1
PF 100%
5.4.2
PF DUTY
5.4.3 ACCEL
5.4.3 DECEL
(Miscellaneous)
Presser foot duty cycle:
Due the voltage is too high to turn a solenoid permanent on all time,
the current is turned on only permanently a short time, after that,
the current has to be chopped.
For example: Duty cycle 40% means 40% on, 60% off
If the duty cycle is too low, the solenoid will not stay on.
If too low, the solenoid will turn too hot!
Presser foot on 100 %
Range
10 to 2000
Steps:
10
Default:
200
Presser foot duty cycle
Range
10 to 100
Steps:
10
Default:
50 (50%)
Acceleration / Deceleration Ramp:
The lower the number, the slower the Ramp!
Acceleration ramp
Range
15 to 50
Steps:
1
Default:
40
Deceleration ramp
Range
15 to 50
Steps:
1
Default:
40
-- 8 --