Dodge 50 Gebrauchsanweisung

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Stromversorgung Dodge 50 herunter. Dodge 50 2 Seiten. Clutch/brake power supplies

These instructions must be read thoroughly before installing or operating this product.
FEATURES
120 VAC Input 50/60 Hz
Full Wave 90 VDC Output
0.80 Amp Rating
Switch Protection
Operates a clutch or brake

SPECIFICATIONS

INPUT: 120 VAC, 50/60 Hz, 1 phase, 100 VA Max.
OUTPUT: 90 VDC nominal, full wave rectified, 0.80 amps Max.
AMBIENT TEMPERATURE: –40°F (–40°C) to 122°F (50°C)
SWITCHING: Supplied by customer.
1. Electromechanical:
Single pole single throw, rated 120 VAC, 1 amp min.
2. Solid state:
Triac, rated 120 VAC, 1 amp min. (off state leakage current
at 2 mA Max.)
WARNING: Because of the possible danger to person(s) or
property from accidents which may result from the improper
use of products, it is important that correct procedures be
followed: Products must be used in accordance with the
engineering information specified in the catalog. Proper
installation, maintenance and operation procedures must
be observed. The instructions in the instruction manuals
must be followed. Inspections should be made as necessary
to assure safe operation under prevailing conditions. Proper
guards and other suitable safety devices or procedures as
may be desirable or as may be specified in safety codes
should be provided, and are neither provided by Baldor
Electric Company nor are the responsibility of Baldor
Electric Company. This unit and its associated equipment
must be installed, adjusted and maintained by qualified
personnel who are familiar with the construction and
operation of all equipment in the system and the potential
hazards involved. When risk to persons or property may be
involved, a holding device must be an integral part of the
driven equipment beyond the speed reducer output shaft.
Instruction Manual for Dodge Model 50
Clutch/Brake Power Supplies
DESCRIPTION
The Model 50 Clutch/Brake power supply is capable of operating
any DODGE clutch or brake within its rating. Switching for the
DODGE Model 50 is done on the 120 VAC input of the power
supply via a customer supplied switch. Internal circuitry provides
suppression of switching transients thus ensuring both fast
response and switch protection.
INSTALLATION
1.
MOUNTING:
The Model 50 power supply may be mounted in any convenient
location using the mounting dimensions shown in Figure 1.
1.070
2.140
Figure 1 - Mounting of Model 50 Power Supply
2. WIRING:
Connections to the power source, switch and clutch or brake
coils as per Figure 2.
Clutch/Brake Connections: Before connecting the lead wires
from the clutch or brake, measure the coil resistance to ensure
it is at least 112 ohms. If two clutches or brakes are used on a
single output, the equivalent parallel total resistance must exceed
112 ohms. This will make sure the power supply will handle the
amperage required. The wire size for making connections should
be consistent with current ratings of the clutch and brake and
length of wire between the power supply, switch, clutch or brake.
WARNING: The user is responsible for conforming to the
National Electrical Code and all other applicable local codes
in respect to wiring practices, grounding, disconnects,
and overcurrent protection. Installation of an approved
disconnecting means in the line side of the controller is of
particular importance. Failure to observe these precautions
could result in severe bodily injury or loss of life.
1
.171 DIA FOR
#8 SCREW
WIRE LEADS ARE
1.140
6" LONG
.570
.625