7. Selectable OUTPUT voltage

8. Over Current Protection (Overload), Over heat protection and reset
Description
Detection
Protection signal
Instructions manual / XS-40D
Limit
Time duration
Protection
LED
Buzzer
Recovery
Over Current Protection
8 A current
Immediately
Whole power shut down permanently
No power
No power
Turn off the power switch
and on after 1 min.
Over Heat Protection
90°C
Turn the power switch off
and on at lower than 90°C
temperature.
7