clivus multrum CM14 Installationshandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Installationshandbuch für Toiletten clivus multrum CM14 herunter. clivus multrum CM14 20 Seiten. Waterless composting toilet systems
Auch für clivus multrum CM14: Installationshandbuch (18 seiten), Installationshandbuch (18 seiten), Installationshandbuch (18 seiten), Installationshandbuch (16 seiten)
FOR BURIED INSTALL SYSTEM ONLY
For a buried system it is required to hold the tank down with galvanised rods. These
are slid into the slots provided on both sides and the front of the CM14 tank.
Installation of
Ø50mm Pipe 1.5M Long
Excavate 300mm larger
than tank all around. Fill
with clean fill.
IMCM-14-2023-12-04
LEFT SIDE VIEW
LEFT SIDE VIEW SECTIONAL IN GROUND
0.5m³ of
concrete over
anchor pipes
Ø50mm Pipe 1.5M Long
Ø50mm Pipe 1.2M Long
ecoflo.com.au
1300-138-182
Installation of
Ø50mm Pipe
1.2M Long
Concrete, sand or
crusher dust 50mm
thick under the tank
7