Stove Performance Results
All efficiencies in table are Net value.
Wood
Parameter
Test duration
h
Total efficiency
%
Nominal heat
kW
output
Approximate
KW
Output range
Mean CO
%
emission (at 13
% O2)
Mean flue gas
ºC
temperature
Flue gas mass
g/s
flow
Mean CnHm
Nmg/m3
emission (at 13
% O2)
Mean NOx
Nmg/m3
emission (at 13
% O2)
DIN Plus
Nmg/m3
particulates (at
13 % O2)
4 | Clock Multi Manual
Large
Standard
Blithfield
Blithfield
0.75
0.86
78.8
84.3
8
5
6.5-10
3.5-9
0.10
0.11
256
227
8.42
3.7
116
72
101
101
19
11
Compact
Double
Contemporary
Blithfield
Blithfield
0.85
0.75
82.3
75.3
5
10.5
3.5 -7
8-12
0.07
0.08
243
365
4.0
8
76
65
107
76
24
13
Brocksford
0.75
81.53
4.77
3.5-7
0.09
206.6
5.19
65.38
75