Clock Woodburners Double 10kw Blithfield Benutzerhandbuch - Seite 4
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Innenkamin Clock Woodburners Double 10kw Blithfield herunter. Clock Woodburners Double 10kw Blithfield 16 Seiten.
Stove Performance Results
All efficiencies in table are Net value.
Wood
Parameter
Test duration
h
Total efficiency
%
Nominal heat
kW
output
Approximate
KW
Output range
Mean CO
%
emission (at 13
% O2)
Mean flue gas
ºC
temperature
Flue gas mass
g/s
flow
Mean CnHm
Nmg/m3
emission (at 13
% O2)
Mean NOx
Nmg/m3
emission (at 13
% O2)
DIN Plus
Nmg/m3
particulates (at
13 % O2)
4 | Clock Multi Manual
Large
Standard
Blithfield
Blithfield
0.75
0.86
78.8
84.3
8
5
6.5-10
3.5-9
0.10
0.11
256
227
8.42
3.7
116
72
101
101
19
11
Compact
Double
Contemporary
Blithfield
Blithfield
0.85
0.75
82.3
75.3
5
10.5
3.5 -7
8-12
0.07
0.08
243
365
4.0
8
76
65
107
76
24
13
Brocksford
0.75
81.53
4.77
3.5-7
0.09
206.6
5.19
65.38
75
21