Operating Instructions
DOHLE Hand Welding Extruder ExOn5
View – controller front – steering box
standard
D - 2381 controller extruder ExOn5 mass
D - 2384 switch heater ExOn2-6
D - 2383 poti ExOn2-6
speed extruder
Display and control elements of the controller front
Temperature unit
AL (Alarm)
Shines if the alarm
exit is on
Controller – desired value setting
All controllers can be changed only in the desired value and are electrnically locked against
wrong inputs.
Change the desired value
The controller indicates actual and desired value temperature at the same time. To change
the desired value temperature proceed as follows:
Do not press these keys.
Downward - key
By every press of this key, the value
becomes smaller, which is indicated
on the desired value display. If this
key is kept constantly pressed, then
the value is sequentially becomes
smaller.
D - 2377 temperature controller ExOn2-6 air
Actual value temperature
tettempevaluetemperatur
Downward - key
DOHLE Extrusionstechnik GmbH
optional
D - 2383 poti ExOn2-6
air flow
Desired value temperatur
Upward - key
Upward - key
By every press of this key, the
value increases, which is indicated
on the desired value display. If this
key is kept constantly pressed,
then the value sequentially
becomes higher.