Data Input Continued
Input Data
Parameter
Batch Reset
Suspend
Batch Value
Time
Date
Torque Min
Torque Max
Angle Min
Angle Max
Units
Programming Data Input:
the ENT key is pressed, the address of where the first byte will be read will be shown. The
user can use the arrow keys to manipulate this value and set it to any desired address or to
DO NOT SEND. Once the desired value is displayed, pressing ENT will store that value. The
ESC key can be pressed to exit without saving.
Number of Bytes
Changing this byte will alter the parameter setting in the unit. Possible
value '0' through '7', 0 through 7, and 'A' through 'H'.
Setting this byte to a non-zero value will reset the batch count.
Setting this byte to a non-zero value will suspend the unit. Set byte back
to zero to un-suspend.
Altering this byte will reprogram the batch value in the current
parameter. If this value is zero, no action will be taken.
Altering this value will reprogram the current unit time with these 6
bytes. HHMMSS format. Both time and date must be legal values for
write to occur.
Altering this value will reprogram the current unit date with these 6
bytes. MMDDYY format. Both time and date must be legal values for
write to occur.
Altering these 6 bytes will change the min torque setting for the current
parameter. Min/Max Torque, Min/Max Angle, and Units must all be
legal value before write will occur.
Altering these 6 bytes will change the max torque setting for the current
parameter. Min/Max Torque, Min/Max Angle, and Units must all be
legal value before write will occur.
Altering these 5 bytes will change the min angle setting for the current
parameter. Min/Max Torque, Min/Max Angle, and Units must all be
legal value before write will occur.
Altering these 5 bytes will change the max angle setting for the current
parameter. Min/Max Torque, Min/Max Angle, and Units must all be
legal value before write will occur.
Altering this bytes will change the units setting for the current
parameter.Possible values 'I'/InLB, 'N'/Nm, 'F/FtLb, 'K'/KgCm, and
'm'/mKg. Min/Max Torque, Min/Max Angle, and Units must all be legal
value before write will occur.
The user has the ability to decide the total number of bytes this unit
with receive as input bytes. The user can also decide which elements
of input data will be received and at what address.
To set the number of input bytes, the user will want to select Num In-
put Bytes from the Data Input sub-menu. After pressing the ENT key,
the user can use the arrow keys to set the number of input bytes.
Pressing ENT will save this value ESC will allow the user to exit with-
out saving a new value. Similarly, each piece of input data can be
located wherever the user desires in the input message. To program
any of the input data, select it from the data input sub-menu. When
14