Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Laborausrüstung Clontech Laboratories His60 Ni Superflow Cartridges herunter. Clontech Laboratories His60 Ni Superflow Cartridges 15 Seiten. Purification of expressed his-tagged proteins from bacterial, yeast, mammalian, and baculovirus-infected cells.
His60 Ni Superflow Cartridges User Manual
C. Buffers – Denaturing Conditions – Guanidine-HCl or Urea
Denaturants, such as 5 M guanidine-HCl or 8 M urea, enhance protein solubility. Because overexpressed proteins
in prokaryotic systems are sometimes insoluble, you may need to purify proteins under denaturing conditions.
When using high concentrations of guanidine-HCl or urea, protein unfolding takes place. On-column refolding or
post-elution refolding is protein-dependent. When purifying proteins under denaturing conditions, we recommend
preparing buffers as indicated below.
Buffers with 6M Guanidine-HCl
Equilibration Buffer: 50 mM sodium phosphate, 6 M guanidine-HCl, 300 mM NaCl, 20 mM imidazole;
pH 7.4
Wash Buffer: 50 mM sodium phosphate, 6 M guanidine-HCl, 300 mM NaCl, 40 mM imidazole; pH 7.4
Elution Buffer: 50 mM sodium phosphate, 6 M guanidine-HCl, 300 mM NaCl, 300 mM imidazole; pH
7.4
Buffers with 8 M Urea
Equilibration Buffer: 50 mM sodium phosphate, 8 M urea, 300 mM NaCl, 20 mM imidazole; pH 7.4
Wash Buffer: 50 mM sodium phosphate, 8 M urea, 300 mM NaCl, 40 mM imidazole; pH 7.4
Elution Buffer: 50 mM sodium phosphate, 8 M urea, 300 mM NaCl, 300 mM imidazole; pH 7.4
NOTE: Samples containing guanidine-HCl cannot be analyzed by SDS-PAGE. A buffer exchange to a buffer
containing urea must be performed before SDS-PAGE analysis. Samples containing urea can be analyzed directly
by SDS-PAGE.
D. Enzymes
Benzonase (Sigma, Cat. No. E8263-5KU)
Recombinant DNase I (TaKaRa, Cat. No. 2270A)
E. Accessories for Automated Purification
A suitable liquid chromatography system (LC procedure only) with 1/16 inch tubing—or a binary pump
system (a quicker and more convenient alternative)
Additional connectors and fittings required to attach the cartridges to a Bio-Rad BioLogic or a classic
FPLC System (Section III.F)
F. Accessories for Syringe-Based Purification
Luer Lock Syringe Fittings (GE Healthcare, Cat. No. 18-1112-51) for syringe-based purification only
M6 FPLC Fittings (GE Healthcare, Cat. Nos. 18-1112-58 & 18-1112-57) for syringe-based or automated
purification
G. Optional
PD-10 desalting columns (GE Healthcare, Cat. No. 17-0851-01) to remove excess imidazole from the
final sample when required for downstream applications