ASHAPOWER NEON-40HV Benutzerhandbuch - Seite 11

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Controller ASHAPOWER NEON-40HV herunter. ASHAPOWER NEON-40HV 14 Seiten. Multi voltage range solar mppt charge controller

ASHAPOWER NEON-40HV Benutzerhandbuch
ERROR
CODE
PV PANEL VOLTAGE
EV
BATTERY BANK VOLTAGE
EB
ET
HIGH TEMPERATURE
EM
TROUBLE SHOOTING
DESCRIPTION
ERROR
ERROR
HARDWARE
FAILURE
PV PANEL VOLTAGE IS NOT IN THE SPECIFIED LIMIT.
CHECK FOR PV PANEL GROUPING. REFER PV PANEL
GROUPING MANUAL PROVIDED.
CONNECTED BATTERY BANK VOLTAGE IS NOT IN
THE SPECIFIED LIMIT. CHECK FOR DEFECTIVE
BATTERIES AND NUMBER OF BATTERIES.
CONNECTED PV PANEL CAPACITY (WATTS) IS NOT
IN THE SPECIFIED LIMIT OR CHECK FOR THE
FUNCTION OF THE COOLING FAN.
LIGHTNING MAY CAUSE HARDWARE FAILURE. IF
CONTINUOUS BEEP SOUND AND ERROR MESSAGE
EM IS SEEN, DISCONNECT THE PV PANELS BEFORE
SWITHING OFF THE DEVICE. THEN SWITCH OFF THE
DEVICE. CONTACT THE INSTALLER FOR SERVICE
ASSISTANCE.
10
SOLUTION