5 Electrical connection
Installation, servicing and troubleshooting of all electrical equipment must be carried out by quali-
fied personnel in compliance with the applicable national and international standard EN 60204-1
and any other EU standards that are applicable in Europe.
The installation of a power supply isolator is required for each motor and power supply to facili-
tate voltage-free work on the electrical equipment. The power supply isolator is not included.
5.1 Electrical Installation
The electrical installation must be made as specified below:
Figure 3: Inside the iDOL 65 box. Make sure that cables and wires are connected as illustrated.
Yellow/green (PE), Blue (N), Brown (P). Use the two cable relief brackets to secure the power cable.
The LAN cable must be led under the plastic bracket and fastened with the enclosed cable ties.
343288
The box is prepared for forwarding the supply from one box to the next.
Network
The camera must have access to the Internet via one of the two Ethernet ports. The Ethernet cable must not
exceed 100m.
The iDOL 65 is equipped with two Ethernet ports LAN 1 and LAN 2, meaning that the iDOL 65 can be con-
nected in series. This means that the network from one iDOL 65 can be forwarded to the next. LAN 1 is used in
direction towards the router and LAN 2 to the subsequent iDOL 65 in the series.
4
Cable tie 200 x 4.8mm
Terminal block
Screw 3x20 TX 10
Cable relief bracket
The enclosed cable glands can be used for cables with an
outer diameter of 6 to 13 mm. If thinner cables with an
outer diameter of 4-6 mm are used, the enclosed split
sealing ring (343288) must be mounted, see picture to the
left.