Handling PC Boards

This upgrade involves handling printed circuit boards. Many components are very
sensitive to static electricity and can be destroyed if static charge on your body
discharges through the component. You do not even have to touch the component to
damage it. Before touching the components on the PC boards, ground yourself by
rubbing the frame of the unit with each hand or wearing an earthing strap.
3

Installation Steps

1. Remove mains power from the CP650 by unplugging the rear-panel power cord.
2. Open the setup control panel access door.
3. Remove the front-panel mounting screw located in the upper right-hand corner of
the setup control panel and carefully pull the front panel toward you to remove it.
4. Remove the seven subpanel mounting screws and carefully pull the subpanel
toward you to remove it. Be sure to support the panel while you perform the next
step.
®
Dolby
UEX/650 Upgrade Kit Installation Instructions
1 2 3
4 5 6 8
7
MAIN
HF
Video Clamp RTA1 RTA2
Mic Bypass
Figure 1 CP650 Control Panel
Figure 2 Remove Control Panel
SERIAL DATA
MIC MUX
Lt
SIGNAL
PRESENT
Rt
Lt
Rt
L
C
R
Ls
Rs
4