CYP AU-D820S Betriebshandbuch - Seite 9
Blättern Sie online oder laden Sie pdf Betriebshandbuch für Verstärken CYP AU-D820S herunter. CYP AU-D820S 13 Seiten. 8 x 20 digital audio switch and distribution amplifier
6.3 RS-232 Protocols
AU-D820S
PIN
1
2
3
4
5
6
7
8
9
Baud Rate: 115,200 bps
Data bit: 8 bits
Parity: None
Flow Control: None
Stop Bit: 1
6.4 RS-232 & Telnet Commands
Command
POWER OFF/ON
INPUT COAX 1~4
INPUT OPTICAL 1~4
STATUS
?/H/HELP
All RS-232 commands will be not executed unless followed with a carriage
return. All commands are case-sensitive.
10
Assignment
NC
Tx
Rx
►
NC
◄
GND
NC
NC
NC
NC
Status
Set Power Status
Choose a Coaxial input
Choose an Optical input
Show Current Information
Show all commands
Remote Control
PIN
Assignment
1
2
3
4
5
GND
6
7
8
9
NC
Rx
Tx
NC
NC
NC
NC
NC