Ashley EC95 Handbuch für Installation und Betrieb - Seite 9

Blättern Sie online oder laden Sie pdf Handbuch für Installation und Betrieb für Holzofen Ashley EC95 herunter. Ashley EC95 20 Seiten. Wood burning circulator heater
Auch für Ashley EC95: Handbuch für Installation und Betrieb (20 seiten), Handbuch für Installation und Betrieb (20 seiten)

Ashley EC95 Handbuch für Installation und Betrieb
FIGURE 8 - CONNECTING HEATER'S CHIMNEY CONNECTOR TO MASONRY CHIMNEY WHEN CHIMNEY CON-
NECTOR DOES NOT HAVE TO PASS THROUGH A COMBUSTIBLE WALL
Before installing the heater, inspect the heater for external damage and missing parts. Check the gaskets around the doors
to assure that they are still in place. Also check inside the heater. Report any deficiencies found to your heater dealer and
make sure all problems are resolved before installing the heater. See figure 12 for illustration of heater parts.
Electric drill 1/4 or 3/8 inch drive
1/8 inch drill bit
Screw driver (blade type and size to fit screws listed below)
No. 8 sheet metal screws (for chimney connector joints)
Gloves and Safety Glasses
Ruler or tape measure
CAUTION:
IF THIS HEATER IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY,
FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT
RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
CAUTION:
DO NOT CONNECT THIS HEATER TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. THERE IS
A SERIOUS SAFETY RISK IF TWO APPLIANCES OR HEATERS ARE CONNECTED TO THE SAME
FLUE.
CAUTION:
THE HEATER MUST BE PLACED ON A LISTED FLOOR PROTECTOR AS NOTED IN THIS MANUAL IF
THE FLOOR IS WOOD OR OTHER COMBUSTIBLE FLOORING. IF CARPET IS PRESENT, IT MUST
BE REMOVED. THE FLOOR PROTECTOR MUST NOT BE PLACED ON CARPET. (SEE FIGURE 5).
CAUTION:
MOST WALLS AND CEILINGS CONTAIN WOOD EVEN THOUGH THEY ARE MADE OF SHEETROCK OR
PLASTER ON THE OUTSIDE. THESE WALLS AND CEILINGS CAN CATCH FIRE FROM THE HOT HEATER
OR CHIMNEY CONNECTOR IF THE HEATER AND CHIMNEY CONNECTOR ARE NOT PROPERLY IN-
STALLED.
MINIMUM CLEARANCE TO COMBUSTIBLE WALLS AND CEILINGS
Minimum clearances to unprotected combustible walls and ceilings as noted by Figures 1 through 4 must be maintained.
Drapes, curtains, furniture and other combustible materials should be kept much further away from the heater to avoid a
fire. If you chose to, you may install the heater and chimney connector closer to combustible surfaces than indicated by
Figures 1 through 4 if a clearance reduction system is also installed to protect combustible ceiling and wall near the heater
and chimney connector. However, there are limits as to how close the heater and chimney connector can be installed to
combustible surfaces protected by a clearance reductions system.
A correctly installed clearance reduction system protects the combustible surfaces well beyond the sides and above the
top of the heater and beyond the sides and top of the chimney connector pipe.
EC95

HEATER INSPECTION

TOOLS AND SUPPLIES NEEDED FOR INSTALLATION

HEATER INSTALLATION

Can or Tube of furnace cement
Floor Protector
Rag or several paper towels
Chimney connector pipes (and elbows, if required)
Pencil
9