Cloud LM-2AW Handbuch - Seite 3

Blättern Sie online oder laden Sie pdf Handbuch für Kontrolleinheit Cloud LM-2AW herunter. Cloud LM-2AW 4 Seiten. Lm-2 series remote mic/line mixer/control modules

Connections
The LM-2 is exceptionally simple to install; the rear OUTPUT
connector is wired to one of the host unit's Facility Ports with a
single screened Cat 5 cable using standard shielded RJ45 connectors
at each end. The Cat 5 cable carries DC power as well as balanced
audio.
Each Zone on the host unit has its own Facility Port, and any LM-2s
connected to a particular port will provide inputs to that Zone only,
and source/level control of the background music in that Zone only.
A second RJ45 connector is provided to permit multiple LM-2s to
be "daisy-chained" together, to provide insert points at different
Connect to
OUTPUT socket
OUTPUT
LINK
LM-2
(UK version illustrated)
Block Diagram
RJ45
Connect to
OUTPUT socket
OUTPUT
LINK
Connect to
LINK socket
Screened
Cat 5 cable
locations in the same Zone. Signals applied to modules wired in this
way will be summed together to the Facility Port to which the "last"
LM-2 in the chain is connected. An internal gating circuit on each
module automatically disables the audio circuitry on any chained
modules which are not in use, to minimise noise contribution.
LM-2s are powered from the host unit to which they are connected,
and each takes 12 mA at +15 V and -15 V. In the vast majority of
installations, the host unit will have ample spare power capacity
for several LM-2s. Full details are provided in the host unit's
documentation.
Connect to
FACILITY PORT
Screened
Cat 5 cable
C l e a r l y b e t t e r s o u n d
RJ45