MAINTENANCE
CLEANING THE STOVE
The stove should only be cleaned when it is cold. The exterior can be dusted with a firm
brush. Do not use a cloth, as this will drag on the paint finish leaving lint on the surface.
From time to time it may be necessary to renovate the exterior by repainting. High
temperature stove paints in aerosol form are available from your stove dealer. Do not
use this form of paint until the stove is cold and always read the instructions on the
container before starting to paint. The door glass is made of a special heat resisting
ceramic and may be cleaned when cold with proprietary glass cleaning liquids and a dry
cloth.
ACCESSING THE CHIMNEY
Cleaning chimneys can be hazardous and should be carried out by a
professional.
The chimney should only be accessed for cleaning when the stove and
flue are cold.
For a top exiting flue the chimney can be accessed through the stove by opening the
door and removing baffle bricks and then the top baffle plate as shown in Fig. 9 .
For a rear exit stove the base of the optional rear flue attachment has a removable base
can be removed to allow access to the chimney.
SHUTTING DOWN THE STOVE (LONG TERM)
The following procedure should be followed if the stove is not to be used for a long
period, summertime for instance. Remove all the ashes from the grate and ash pan and
use a vacuum cleaner nozzle to clean ash from the base of the stove. Remove the baffle
plate and brush the flue ways. Close the door and open the air inlets fully. This action
will allow air circulation through the flue ways and help avoid corrosion and
condensation.
SERVICING
Regular maintenance should be carried out by a competent engineer.