TROUBLE SHOOTING
PROBLEM
INDICATOR
Blue light in the
sensor flashes
(once) and the
soap pump
operates.
Foam is not
dispensing
from spout
Blue light in the
sensor does not
flash (once) when
the users' hands
are within the
sensor range.
1
|
Dolphin Blue
|
BC632F
CAUSE
Soap has run low or is completely
out.
The soap tank has been lled, but
soap has not reached the spout.
The connectors between the pump
and the electronic unit are not
connected properly.
The pipe for the speci c dispenser
is bent or curved and does not reach
the bottom of the soap tank.
Filter is clogged.
Sensor is picking up reflections from
the washbasin or another object.
Connectors between the electronic
unit and power source are
disconnected or not properly
connected.
SOLUTION
Re ll the soap tank.
Refer to page
Press the re ll button located
at the bottom of the pump
to prime the soap until it is
dispensed from the spout.
Connect the connectors
properly so that the white
o-ring is not visible.
Make sure the pipe is adjusted
inside the tank for an ideal
soap intake.
Clean or replace the lter.
Refer to page
Eliminate the cause of
reflection.
Properly connect the
electronic unit connectors to
the power source connector.