Asian Electron Extron AS Gebrauchsanweisung - Seite 13

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Inverter Asian Electron Extron AS herunter. Asian Electron Extron AS 18 Seiten. 1u 19”/23”/ open rack inverter

Asian Electron Extron AS Gebrauchsanweisung
Model No
YK-PSW121KVAE
YK-PSW241KVAE
YK-PSW481KVAE
Model No
YK-PSW122KVAE
YK-PSW242KVAE
YK-PSW482KVAE
Also, use only high quality copper wiring and keep cable length short from 3-6 feet.

2-7 Inverter Operation:

To operate the power inverter, turn it on using the ON/OFF switch on the front panel. The
power inverter is now ready to deliver AC power to your loads.
If you are operating several loads from the power inverter, turn them on separately after the
inverter has been turned on.
This will ensure that the power inverter does not have to deliver the starting currents for all
the loads at once.
2-7-1 Controls and indicators:
The ON / OFF switch turns the control circuit in the power inverter on and off.
The Inverter operates from an input voltage ranging from :
10.0 to 16.0 VDC for 12V models
20.0 to 32.0 VDC for 24V models
42.0 to 62.0 VDC for 48V models
The Inverter will indicate high and low DC voltage conditions as follows:
Model
YK-PSW121KVAE
YK-PSW122KVAE
YK-PSW241KVAE
YK-PSW242KVAE
YK-PSW481KVAE
YK-PSW482KVAE
2-7-2 Output Voltage Indicator:
LED displays light on VAC as show as output Voltage value
2-7-3 Output Current Indicator
LED displays light on AMP as show as output current value
DC Input over
voltage shut-down
16.0VDC
32.0VDC
62.0VDC
Wire AWG
#2
#4
#6
Wire AWG
#2/0
#1/0
#2
DC Input over
DC Input under
voltage alarm
voltage alarm
15.5VDV
31.0VDC
61.0VDC
12
Inline Fuse
150A
80A
40A
Inline Fuse
250A
125A
70A
DC Input under
voltage shut-down
10.5VDC
10.0VDC
21.0VDC
20.0VDC
43.0VDC
42.0VDC