Ambic Equipment Ltd – EasiDoser™ Operating Notes
If Optional Level Probes (e.g. AFF/200-50-10 – Float Switch Assembly for 20-25 Litre Container) are fitted,
LOW level of Chemical activates Float Switch as below:-
Sounder will operate 3 times every 2-3 seconds.
Sounder sequence will continue to operate at 1 minute intervals.
Warning Displays (as shown above) will alternate with the normal run displays.
When the container is refilled/replaced, the Sounder and Warning Displays stop automatically only
when the pump makes its first Dispensing cycle after refill.
Sounder CANNOT be muted until level of Chemical rises above "LOW".
Initial Set Up – Priming & Setting up the system ready to use
Switch on the power at the electric socket and on the front of the pumping unit. Set the program for direct
mode. Press the appropriate button in the front of the unit to activate the required pump and liquid will start
to be drawn up through the pump(s). Allow unit to run until liquid has passed through the pump(s) and is
flowing out in a continuous stream from the end of the distribution pipe. Reset the direct mode to your
required setting.

Operation

Depending on the set up of the unit the pump(s) will either run for a set duration or continuously until the
signal is removed:
Manual mode – pressing the dose button for 1 second activates for a set duration.
Signal mode – receipt of either a 12-24V DC or a 12-230V AC signal activates for a set duration.
Direct mode – receipt of either a 12-24V DC or a 12-230V AC signal activates the unit and it will run
continuously until this signal is removed.
WARNING – Refill chemical container(s) BEFORE IT IS EMPTY and SWITCH OFF PUMP
UNIT whilst refilling.
system as described in the "Initial Set Up section" above.

Maintenance

In order to preserve the efficiency and reliability of the EasiDoser™ system, we recommend that the
following parts be inspected regularly for physical wear and replaced EVERY 1 – 2 YEARS, depending on
the chemical used and the frequency of use.
Peristaltic pump tubes
Inlet tube filters (part ATS/419).
For optimum results and safety use all the parts supplied by the manufacturer.
In the event that chemical supply is exhausted, it will be necessary to re-prime
- Grease the tubes with silicone every six months
- Clean regularly with warm water
-14-