ambient power AP089 Benutzerhandbuch - Seite 6

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Messgeräte ambient power AP089 herunter. ambient power AP089 7 Seiten. Meter clock

ambient power AP089 Benutzerhandbuch
11th May 2021
AP089 Meter Clock
Page of
6
7

Care

General

Do not subject the unit to sharp shocks or excessive vibration. Place on a flat, level surface.

Cleaning

Clean the unit with a damp cloth or using mild spray furniture polish. Avoid excessive liquids.

Calibration

The unit is adjusted and calibrated when manufactured and should not need adjusting. Meters may exhibit some
non-linearity, more noticeable on the hours scale. This may be noticeable around the midday points where the
pointer may be a few degrees off of the indicated time. However, zero and 23 hours (or 59 minutes) should be
accurate. If they are not, then the unit can be calibrated as follows:

Zero Adjustment

With the power off, adjust the flat screw on the front of the meter so that the needle indicates zero.

Full Scale Adjustment

Remove the four screws on the front of the enclosure and GENTLY lift
away the panel. It is secured by wires so cannot be completely removed
- you need to observe the meters to adjust anyway. Apply power and
enter OTA mode - however, do not upload firmware. The unit indicates
full scale. Inside the unit are screws on potentiometers marked 'Hrs',
'Mins', 'Secs' (where fitted). Each of these can be carefully adjusted to
present a full scale measurement (24/60/60 as appropriate) while the
unit is in OTA mode. Make sure that the meters are oriented the same as
they are for normal operation (normally vertical). Be careful not to touch
any other parts within the unit apart from the adjustment screws.
E&OE