Ambient Technologies RCSITEA Benutzerhandbuch - Seite 8

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Fernsteuerung Ambient Technologies RCSITEA herunter. Ambient Technologies RCSITEA 12 Seiten. Thermostatic on/off, flame height adjustment and blower remote control 120 vac

Flame Height Setting for Thermostatic Mode:
1. Hold AUTO/FLAME button for 5 second and one number and flame icon will
show up in LCD screen, as show in the right figure.
2. Use the ON / Δ or OFF / ∇ button to set the desired flame height to 1 (Min), 2
(Medium) and 3 (Max)
3. If there is no input within 3 seconds, the new setting will be transmitted to
receiver. This setting only affects auto mode operation.
4. The default setting for transmitter is 2 (Medium), as shown in left picture.
Low Battery Detection:
1. Battery voltage is checked once a minute. When the battery voltage drops to a
certain level, the low-battery icon will display on LCD, and the transmitter will
turn off the appliance. The transmitter will not function anymore until fresh
batteries are installed.
2.
When the batteries are low, the LCD displays a low battery indicator. The low
battery indicator will be displayed in any mode.
3. The transmitter will not operate with low batteries. Change the batteries before the batteries are too weak
for normal operation. TURN THE UNIT OFF BEFORE REPLACING BATTERIES.
Child-Proof Protection:
1. Press and hold the ON and OFF buttons simultaneously for 3 seconds to enter
childproof mode as shown in this picture.
2. The transmitter will not send a signal again until childproof mode is deactivated by
pressing the ON and OFF buttons simultaneously for 3 seconds to exit childproof
mode and the Childproof indicator disappears from LCD.
Transmitter Thermal Shutdown:
1. If transmitter measures a room temperature exceeding 99 degrees Fahrenheit, the
LCD will display "HI" and the transmitter will turn off the appliance.
2. Transmitter will not function until the room temperature has dropped below 99
degree Fahrenheit. If transmitter measures a room temperature less than 40
degrees Fahrenheit, the LCD will display "LO" and NO SIGNAL will be sent to
turn on the appliance.
Receiver:
Slide Switch:
1.
ON position: the main burner will ignite and blower will come on when Blower on Delay Time is reached
and fan speed has been enabled, the flame height is max; otherwise just burner will ignite until the slide
switch is placed in the OFF or RS position to turn burner off.
50D0111
RCSITEA Installation & Operating Manual
Rel 1.0 April 2009
Page 8 of 10
A Division Of Monessen Hearth Systems
Ambient Technologies