If this unit is to be installed in a smoke controlled area the manufactures
permanent stop must be fitted to the secondary air control in all
circumstances.
To install the smoke exemption square,
Firstly fully open the secondary slider by pushing the handle fully to the
right
Insert the square into the far left of the secondary channel and tap into
place using a hammer or other suitable tool
The square is correctly fitted when it is flush with the front casing
The smoke exemption square should be fitted by a competent person as
part of the original commissioning process and once installed should not
be removed.
The appliance is supplied assembled with the flue spigot in the top exit
position.
If you intend to install the appliance using a rear flue connection, the
blanking plate should be swapped over as follows:
 Remove the internal baffle plate
 Remove the blanking plate retaining bar internally.
 Remove the flue spigot from the top exit by removing the securing
bolts and rope seal.
 Refit the rope seal and flue spigot to the rear exit and secure with the
bolts. Seal with fire cement.
 Refit the blanking plate to the top exit using the rope seal and retaining
bolts.
 You may remove the rear air intake spigot if not using the direct air kit

Assembly of the unit