description
The sensor has an automatic standby system. Is activated after 20 transmissions of the vibration sensor. The standby time is 2 mi-
nutes. Therefore, in normal operation the system, after a first violation, it will remain in standby for 2 minutes before returning to
operational. All this is aimed at low battery consumption. The reed contact does not go into standby.
The supervision is an automatic transimission done by the device, elapsed an adjustable time period without opening or closing of
the linked contacts.
This mechanism allows to the receiver to signal problems of communications. The time set for this function is 60 minutes, with a
maximum of 24 daily transmissions.
The internal led of SS400 is turned on during the transmission of the device when the switch tamper is open. It is turned off when
the tamper is closed. The notification of battery level is automatic and it's managed directly from the receiving equipment.
installation – storage
Start with the activaction of the device removing the tongue under the battery.
To store the device it's needed to follow the procedure of the receiver, using the LEARN key to send the storage signal.
Note: for the entire procedure see the manual of the receiver.
When the device is placed, use the test tool of the receiver for verify the wireless range, the correct closing of the box, the status
of the battery, ... Use the sensivity trimmer for regulation the vibrations. Is recommended to use for windows, stained glass, or
walls to protect against impact. In order to have the correct operations of tamper, place a screw on the bottom part of the box,
like indicated in the following picture.
technical specifications
Measures
Battery
Consumption: (depending on the usage)
Maximum consumption on transmission
Antiremoval/Antiopening
Working Frequency
Minimum Wireless Range (open space)
Environmental Conditions
The installation must be done from specialized people.
The manufacturer declines each responsability if the product is tampered from not authorized people.
It's suggested to verify the correct operations of the system at least one time for month. However a reliable alarm system doesn't avoid intrusions, robbery, fire or
other, but it reduces the possibility that these situations happen.
www.amcelettronica.com
Antiremoval
screw
L77 H36 P20 mm
CR2450
from 1 µA to 4µA
19mA
YES
433,92 MHz
200mt
from +5°C to +40°C
SS400 IT-EN v1.1