Flo Fab 1000/1004-IC11/2H-5-2-1 Manual de instalación, uso y mantenimiento - Página 11
Navegue en línea o descargue pdf Manual de instalación, uso y mantenimiento para Bomba de agua Flo Fab 1000/1004-IC11/2H-5-2-1. Flo Fab 1000/1004-IC11/2H-5-2-1 12 páginas. 1 - 15 hp @ 3500 rpm end suction centrifugal pumps
Risk of electric shock. Always disconnect the pump from the power source before handling inspections or repairs.
PROBLEM
A) The pump does not prime,
the vacuum gauge indicates a
lower reading than normal.
B) The pump does not prime,
the vacuum gauge reading
indicates higher than normal.
C) The pump priming good
vacuum gauge reading is
normal, the manometer
indicates a lower pressure than
normal.
D) The pump priming good
vacuum gauge reading is
almost normal, reading the
manometer is greater.
E) The pump loses its priming
during operation, vacuum
gauge reading drops to zero.
F) The pump priming pumps
well and satisfactorily but noisy.
G) Motor overload.
NOTE: Flo Fab Pumps assumes no responsibility for damage or injury due to disassembly in the field. Disassembly of the pumps or supplied accessories other
than at Flo Fab Pumps or its authorized service centers, automatically voids warranty.
PROBABLE CAUSE
- Threaded joints in the suction tightness.
- Gaskets for no wear.
1. Air leak in the suction
- The mechanical seal for leaks.
system.
- The drain plug has leaks.
- The vacuum gauge may be leaking.
2. Insu cient liquid in the
- T
pump casing.
3. Low operating speed.
- The motor speed (RPM).
- Impeller rotates freely.
4. Bound pump.
- Internal parts are clean.
5. Mechanical defect.
- That the internal parts are not worn.
1. Pipe clogged suction.
- The suction line is clean.
1. The pump speed is very
- The voltage is correct.
low.
2. Mechanical defects.
- The internal parts for wear.
- The discharge is clear of obstructions.
1. Discharge obstructed.
- That the discharge valves operate correctly.
1. suction dynamic level
- When the pump is operating, never lacks
too high.
water in the suction.
- For leaks in suction piping, anges and Ā
gaskets.
2. The pump is sucking air.
- That there is no vortex e ect at the end of
the suction, this lack of water.
- That screws are tight at the base.
1. Pump base is loose.
- There are no cracks in the base.
- The dynamic level is not too high
- That the pumping capacity is not too much.
- The pump is operating in the range of NPSHR
2. Cavitation.
- If r
the problem is in the point above; partially
close the discharge valve.
- The bearings for wear.
3. Bearings.
- That there is oil in the deposit.
- The impeller does not have any foreign
material.
4. Vibration.
- The pump is operating in the range.
- That the alignment is correct.
1. Low Voltage.
- The voltage is correct.
- The amperage of the plate is not exceeded.
- There is no foreign material that may force
2. Overload.
the impeller.
- That the motor is suitable for the pump.
Troubleshooting Chart
CHECK
er.
w makes the noise gone, then
10