Amcor ALTL -12,000EH Manual del usuario - Página 6

Navegue en línea o descargue pdf Manual del usuario para Aire acondicionado Amcor ALTL -12,000EH. Amcor ALTL -12,000EH 8 páginas. Cooling and heatpump heating air conditioner
También para Amcor ALTL -12,000EH: Manual del usuario (16 páginas)

Amcor ALTL -12,000EH Manual del usuario

Before Use

Important!
• Leave the unit in an upright position for at least 2 hours before use.
• Always place the unit on an even surface.
• The power cord has a built-in L.C.D.I. (Leakage, Current, Detection, Interruption) circuit
breaker for added safety. If the power supply is interrupted, please press the reset
button to reconnect the unit to the power source. The green light should be on.
• Make sure the unit is connected to a correctly grounded power supply.
• For proper operation, the unit must be vented to the outside.
• Do not cover or obstruct the appliance inlet or outlet grilles.
• To avoid the risk of shock, the product should never be used in bathrooms, shower rooms
or in any other steamy or wet areas.
• Always transport the unit in an upright position.
• Do not sit or stand on the unit.
• Do not place objects on the unit.
• Do not touch the unit with wet/damp hands or when standing barefoot.
• Drainage of the water container is required before moving the unit or
putting it into storage.
• If the electric socket is different from the plug provided, have a professionally qualified
electrician replace the outlet with a suitable one. Avoid the use of adaptor plugs, multiple
sockets and/or extension cords; if their use is necessary, ensure that they conform to the
current safety regulations.
• Do not pull the power cord or place it near a source of heat; always unroll it completely
to avoid the possibility of dangerous overheating.
• If the power cord is damaged, it must be replaced by a qualified person.
THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE
INSTRUCTIONS ARE NOT FOLLOWED.
4
Operation
Programming the timer for ON - when the unit is OFF.
• Perform the standard steps as described above.
The circular time scale will be on between the ON
programmed times until 24:00. The flashing bar on the
time scale indicates the real time and moves a segment
ahead every 30 minutes until it reaches the ON timer
time, then the black segments in the circular time scale will disappear.
Programming the timer for OFF - when the unit is RUNNING.
• Perform the standard steps as described above.
The circular time scale will be on between the present time to the OFF programmed time.
The flashing bar on the time scale indicates the real time and moves a segment ahead every 30 minutes
until it reaches the OFF timer time, then the black segments in the circular timescale will disappear.
Repeat OFF and ON
Programming the timer for repeat OFF and ON - when the unit is RUNNING.
• Perform the standard steps as described above.
• Repeat the above procedure while the digits are still flashing for setting the ON.
The circular time scale will be ON between 00:00 to the time set with the timer to OFF and
from that time until 24:00. The flashing bar on the time scale indicates the real time and moves a segment
ahead every 30 minutes. The unit will operate daily according to the timer setting.
Repeat ON and OFF
Programming the timer for repeat ON and OFF - when the unit is NOT RUNNING.
• Perform the standard steps as described above.
• Repeat the above procedure while the digits are still flashing for setting the OFF.
The circular time scale will be OFF between 00:00 to the time set with the timer to ON and
from that time until 24:00. The flashing bar on the time scale indicates the real time and
moves a segment ahead every 30 minutes. The unit will operate daily according to the timer setting.
After a power failure, or after the unit has been unplugged, you will have to program the
timer settings again.

Canceling the Timer Function

In order to cancel the timer programming press the button momentarily, then it will
return to the time display. The daily mode will be cancelled as well. The black segments in
the circular time scale will disappear.
:00
24
18:00
18:00
06:00
06:00
12:00
9
00:00