Cleaning and Maintenance

Always disconnect the unit from the electrical outlet prior
to cleaning or servicing the unit!
Note that the servicing intervals mentioned in this section are
based on air purifi er use of 24 hours a day (continuous operation)
in a normal household environment. If your use of the air purifi er
differs from that described above, then you can adjust the servicing
intervals accordingly.
1. Clean the outside of the AM-12 and the area around the air
purifi er with a soft damp cloth once every 2 weeks.
2. The Dust Collector Plate assembly is the part of the unit
that collects the dirt and needs to be cleaned periodically.
the Dust Collector Plate assembly is removed by pulling it
out the top of the unit. The stainless steel plates of the
Dust Collector Plate assembly should be washed in warm
soapy water once a month.
At the bottom of the Dust Collector Plate assembly is a fl exible
tab. This tab cleans the ionizing needles inside the unit when the
Dust Collector Plate assembly is removed from or inserted into
the AM-12.
Care should be taken not to damage the tab during the
cleaning operation.
Make sure that the Dust Collector Plate assembly is
completely dry before reinstalling it.