CO Guardian 353R Manual del usuario
CO Guardian LLC
1951 E. AIRPORT DRIVE
TUCSON, AZ. 85706
g. Install the TEST/RESET and the amber ALERT annunciator in a location within the
pilot's direct field of vision and within normal pilot's reach. Note: see MFG MFD
installation manual if TEST/RESET and the amber ALERT annunicator unit will not be
installed and the data will be displayed thru the RS232 interface with MFD. See
Manufacturers manuals for proper wiring guidance.
h. The remote unit can be remotely installed behind the instrument panel up to six inches
from the panel air sampling holes. Verify there are no bends that may obstruct air flow to
the unit.
i. The panel mount unit can be installed anywhere around the instrument panel within pilots
reach. Verify that there is no obstruction of airflow to the unit.
j.
INSTALLATION 353R using drawing (353-001 Rev. Orig or later)
6.1
Installation 353R using drawing 353-001 Rev. Orig or later
a. Choose a location behind the instrument panel for the installation of the CO Detector.
Choose a location with space available that also meets the following criteria. A typical
installation is shown in the attached drawing. The unit can be installed on any side of the
instrument panel.
b. Insure that the area around the CO Detector panel location will permit unrestricted
airflow through the unit.
c. Install in a cockpit area not exposed to excessively dusty or dirty conditions.
d. Insure that the air intake on the front of the CO Detector is not obstructed in any manner.
e. Install the CO Detector in a location without high or disturbed airflow movement. The
CO Detector will detect the presence of CO more effectively if the unit does not have air
blowing over it.
f. Insure that the CO Detector installation area meets the temperature and humidity ranges
listed in the List of Particulars specifications. Temperature and humidity conditions
outside the specification may affect the sensitivity of the detector.
g. Install the TEST/RESET and the amber ALERT annunciator in a location within the
pilot's direct field of vision and within normal pilot's reach. Note: see MFG MFD
installation manual if TEST/RESET and the amber ALERT annunicator unit will not be
installed and the data will be displayed thru the RS232 interface with MFD.
353 FAMILY MODEL OWNERS/INSTALLATION MANUAL
Document: 353-002
Date: 11/15/05
REV ORIG.
Page 9 of 17