Amdi TECH-SCAN32 PLUS Hoja de instrucciones - Página 5

Navegue en línea o descargue pdf Hoja de instrucciones para Escáner Amdi TECH-SCAN32 PLUS. Amdi TECH-SCAN32 PLUS 7 páginas.

Amdi TECH-SCAN32 PLUS Hoja de instrucciones
PROGRAMMING THE ENVIRONMENTAL CONTROL LOCATIONS:
1.
Place the unit face down on a flat surface so that the bottom is seen.
2.
Set the level Select switch to ECU (level 1).
3.
Remove the screw holding the door for the keypad closed.
4.
Remove the door by pressing the clip forward and unlocking the door.
The programming keypad will be visible (see diagram – Programming Keypad).
5.
6.
Turn the power ON by turning the Volume control clockwise.
7.
Plug in the remote AC outlet device or Remote Light Bulb to be controlled either into an AC outlet or into a light
socket. When power to the Remote Light Bulb is applied, the light bulb will turn ON.
8.
Slide the PROGRAM switch RF SW1 up to the ON position.
9.
Dial in the 9 digit Programming ID code (see diagram REMOTE AC OUTLET & REMOTE LIGHT BULB) from
the device that you are going to control using the keypad (the Programming ID code is labeled on each device).
The numbering sequence for the keypad (see diagram – BOTTOM VIEW) is from the top left A=1, B=2, C=3,
D=4, E=5,
10. After entering the 9 digit ID code press OK (bottom middle button on the keypad). The LED on the remote AC
outlet will turn on. The Remote Light Bulb will turn OFF.
11. Select the position you want to store the Programming ID code into: A, B, C or D on the left side of the keypad in
the ON column. A is for the first position (J1 on the diagram GRID VIEW) top left position on the front of the
device.
B is for the next position to the right (J2), C is for (J3) & D is for (J4). All the top membrane positions (
J1 to J4)are used to turn ON the remote devices. (J5 to J8) will turn OFF the remote devices. Once you program
the membrane position on top to turn ON a remote device, the OFF position below it is automatically programmed
to turn OFF the remote device.
12. Press the OK button again, the LED on the remote AC outlet will flash and the Remote Light Bulb will flash on
and off, this means the membrane position is programmed.
13.
Slide the PROGRAM switch RF SW1 down to the OFF position.
14.
Repeat steps 6 thru 12 for the next remote device. You can program up to 8 remote devices into each ON position.
Once the ON position is programmed, the OFF position is automatically programmed.
15.
The 4 remote devices that come with the Tech/Scan 32 Plus ECU are already preprogrammed. The colored dot on
each remote device relates to the position where it is programmed. RED is for position J1, BLUE is for position J2,
GREEN is for position J3 and YELLOW is for position J4.
(top right), A - =6, B - =7, C - =8, D - =9 & E - =0.