TO LIGHT THE STOVE
If the pilot is not alight, follow procedure to light pilot.
Turn the control knob anti-clockwise until the full on
position (
) (See Fig. 13). The main burner will light. At
this setting the pressure should be 17.7+/-1.0mbar with
an inlet pressure of 20mbar for natural gas or 36 +/-
1.0mbar with an inlet pressure of 37mbar for propane.
Depress and turn the control knob clockwise to the pilot
position (
) (Fig. 14). The stove will go out and the pilot
will remain alight. Remove the pressure gauge and
replace the test point sealing screw.
Turn stove to maximum setting (
for gas soundness.
TO TURN STOVE OFF
Turn the gas control knob to the minimum gas rate
position (
) (Fig. 16), slightly depress the control knob
and continue turning to the pilot position (
The fire will go out, and the pilot will remain lit and may
be left on permanently.
TO TURN STOVE AND PILOT OFF
Turn the stove off as described. Depress the control
knob, turn to the off position (●) (Fig. 18) and the pilot will
go out.
) (Fig. 15) and check
) (Fig. 17).
9
FIG. 13
FIG. 14
FIG. 15
FIG. 16
FIG. 17
FIG. 18