Acer AL1602W Manual de servicio - Página 8
Navegue en línea o descargue pdf Manual de servicio para Monitor Acer AL1602W. Acer AL1602W 45 páginas.
Electrical Requirements
Standard Test Conditions
All tests shall be performed under the following conditions, unless otherwise specified.
Ambient light
Viewing distance
Warm up time
Analog Input signal
Control temperature
User brightness control
User contrast control
Picture position and size
Viewing angle
AC Supply voltage
Ambient temperature
Display mode
Measurement systems
The units of measure stated in this document are listed below:
1 gamma = 1 nano tesla
1 tesla = 10,000 gauss
cm = in x 2.54
Lb = kg x 2.2
Degrees F = [°C x 1.8] + 32
Degrees C = [°F - 32]/1.8
u' = 4x/(-2x + 12y + 3)
v' = 9y/(-2x + 12y + 3)
x = (27u'/4)/[(9u'/2) - 12v' + 9]
y = (3v')/[(9u'/2) - 12v' + 9]
nits = cd/(m2) = Ft-L x 3.426
lux = foot-candle x 10.76
Dark room (< 1 cd/m2)
40 cm for LCD performance, 20 cm for LCD failures
>30 minutes
700 mVss
6500° K
The value under user mode
Set to The value under user mode, which allows that the brightest
two of 32 linear distributed gray-scales (0~ 700mv) can be
distinguished.
Factory preset value
110°H and 85°V (CR>5)
90°H and 65° (CR>10)
220V± 5%, 50±3Hz
20+5℃
1360x768, 60Hz, full white pattern
8