Acer AL1917W C Manual de servicio - Página 7
Navegue en línea o descargue pdf Manual de servicio para Monitor Acer AL1917W C. Acer AL1917W C 44 páginas. 19-inch flat panel active-matrix tft lcd
También para Acer AL1917W C: Manual del usuario (10 páginas), Manual del usuario (16 páginas), Manual del usuario (11 páginas), Manual (12 páginas), Manual (12 páginas)
Acer
3. Electronic Circuit Theory
3.1 Switching Mode Power Supply
3.1.1 AC Current Input Circuit
P801 is a connector for connecting AC Power. F801 is a fuse to protect all the circuit. AC input
voltage is from 90v to 264V. R801 and R802 joined between two inputting main circuit to prevent
man from shock. L801 is used to clear up low frequency wave. C801 and C802 are used to discharge
the waves that L801 produced. High frequency waves are damped by C801 and C802. D801 is a
rectifier which composed of 4 build-in diodes, it inverts AC to DC.
3.1.2 High Voltage to Low Voltage Control Circuit
C804 is used to smooth the wave from rectifier. IC802 is a highly integrated PWM controller.
When rectified DC high voltage is applied to the HV pin during start-up, the MOSFET Q804 is
initially off, and the Vcc pin capacitor is charged. When the Vcc pin voltage reaches approximately
10V, the control circuitry is activated and the soft-start begins. The soft-start circuit gradually
increases the duty cycle of the MOSFET from zero to the maximum value over approximately 4ms. If
no external feedback/supply current is fed into the FB pin by the end of the soft-start, the current
Setpoint will be above the fault level, FAULT flag is raised, if the FAULT duration exceeds 80ms, the
output controller disable
Resistor R808, R809, R810, R811 are for line over voltage shutdown(OVP)
When PWM is turned off, the main current flow will be consumed through R804 and D802, This
will prevent MOSFET Q804 from being damaged under large current impulse and voltage spike.
D803 and C807 to provide internal Auxiliary voltage to Vcc pin during normal operation.
Otherwise, error amplifier and feedback current input the FB pin for duty cycle control.
3.1.3 DC_5V and DC_14V Output Circuit
For DC 5V, D805 is used to rectify the inducted current. R828 and C814 are used to store energy
when current is reversed. The parts including C818, C822, C820,L803 are used to smooth the current
waves.
For DC 14V, D803 is used to rectify the inducted current. R827 and C813 are used to store
energy when current is reversed. The parts including C815, C817 and L802 are used to smooth the
current waves.
3.1.4 Feedback and OVP Protect Circuit
Pin R of IC803 is supplied 2.5-v stable voltage. It connects to 5V and 14V output through R822,
R823 and R824. R822, R823 and R824 are output sampling resistor. When the sampling voltage more
than 2.5V or less than 2.5V, current of FB IC802 will change, this can change the voltage from T801.
OVP Protect Circuit: When output is overvoltage, the auxiliary winding voltage will be increased,
when it reaches about 14V. Q803 is triggered . It makes the IC802 Pin 1 exceed 5V, then the IC802
output will be disabled.
Q801, R816, R817 and ZD803 make up of dummy loading circuit. For start-up sequence, during
5V output take place high loading first, this dummy loading circuit operated to insure 14V not be
increased.
3.2 I/F Board Circuit
3.2.1 RGB CAPTURE
- Signal RED,GREEN,BLUE input through CN103 #1,#2,#3, Stop DC via C112, C114 and C116,
and then enter into U105 (scaler) analog input terminal #18,#20,#23, and then scaler deals with
signal internally. TVS101, TVS102, TVS103 are ESD protector to prevent U105 from ESD.
- Signal DDC_SCL (series clock) inputs via CN103#15, and then passes through ZD101 Zener for
ESD protection, goes into U105 #31.
- Signal DDC_SDA (series data) inputs via CN103#12, and then passes through ZD107 Zener for
ESD protection, goes into U105 #30.
- Signal TTL vertical sync. (Vsync) inputs via CN103 #14, and then clamped by ZD105 Zener,
passes through R129, and then goes into IC U105 (scaler) #28.
6
Service Manual