1.0 INTRODUCTION

American Rotary specializes in converting single phase electrical power to three phase electrical power . The
three-phase output is delta configured . Most machinery requires a delta three phase voltage and this third
line voltage to ground should not affect operation . If a piece of equipment requires wye voltage and a neutral
connection, the output of the phase converter must be run through a delta-wye transformer to create the
neutral . The phase converter must be started before the transformer is connected electrically . This is done with
a safety disconnect switch . American Rotary can provide these transformers and disconnect switches if needed
by calling 888-743-6832 .

2.0 INSTALLATION

Your AMP phase converter from American Rotary has been designed to be completely plug and play for your
convenience . The AMP has come equipped with the necessary components for easy connection and set-up
(installed features may vary) .
STEP ONE
To connect to your single phase power supply,
use the provided Nema 6-50P single phase plug .
(Customer requires a 208v-240v Nema 6-50R three
prong single phase female receptacle . If you do
not have a receptacle, you can purchase them at
American Rotary by calling 888-743-6832 .)
STEP TWO
Connect the three phase load using the pre-
installed three phase receptacle . (If you do not have
a receptacle, you can purchase them at American
Rotary by calling 888-743-6832 .)
STEP THREE
Turn on the AMP rotary converter by pressing the
START button located on the front of your converter .
This is a magnetic starter intended to start the
rotary phase converter . It is not designed or
intended to be able to start your load . If you do not
have a motor starter for the intended load, one can
be purchased through American Rotary by calling
888-743-6832 . To turn off the converter, use the red
button labeled STOP also located on the front of the
panel . See STARTING AND STOPPING on page 10
for more information .
7 | User Manual R2 .3
STEP FOUR
Place your pre-installed breaker to the on or up
position . This breaker is located above the installed
receptacle .
STEP FIVE
Turn on the power to your load and enjoy having
quality three phase power at your fingertips .