American Safe Room ASR-200-AV-NBC Safe Cell Manual de instalación y funcionamiento - Página 16

Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Limpiador de aire American Safe Room ASR-200-AV-NBC Safe Cell. American Safe Room ASR-200-AV-NBC Safe Cell 19 páginas. Nuclear, biological, and chemical overpressure filter system

Specifications — filters
Pre-filters
Two piece polyester pre-filter that protects the HEPA from being loaded up with larger airborne
particles. The first one is for large particulates, the second is for finer particulates.
HEPA particulate filter
Protects personal against fallout particles, toxic aerosols, and biological warfare agents.
CERTIFIED TO MEET OR EXCEED MIL F 51079-1998
The nuclear grade media furnished in these filters is certified to meet the requirements of the: Israeli
Ministry of Defense and the U.S. Army.
MIL-F-51079D as required in the US Army document for:
Design Of Collective Protection Shelters To Resist Chemical, Biological and Radiological (CBR) Agents,
Us Army Corps of Engineers ELT 1110-3-498 24 Feb. 1999.
EN 1822-1-1998
High efficiency air filters: Classification,
Performance testing and marking.
Media
Cell Side Material
Separators
Bond:
Gasket Material
Gasket Location
Factory Test
UL 866 Label
HEPA filter cell
As developed by the Atomic Energy Commission and used in nuclear power stations, hospitals and
bio-containment laboratories.
Guaranteed Performance
Each HEPA filter is individually tested before it leaves the factory, your assurance that it meets rated
efficiency. The penetration and actual airflow rate are indicated on the label. Each filter is also
assigned a serial number.
Water repellant glass micro fiber 99.97% true HEPA type (A).
Fire retardant particleboard
Aluminum
Polyurethane foam
Neoprene (RE43E1)
Both sides
Certified 99.97% (DOP)
Required
ASR-200-AV-NBC Safe Cell
Installation and Operation Manual
Revision C - April 27, 2016
Section
L