American Safe Room ASR-200-AV-NBC Safe Cell Manual de instalación y funcionamiento - Página 7

Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Limpiador de aire American Safe Room ASR-200-AV-NBC Safe Cell. American Safe Room ASR-200-AV-NBC Safe Cell 19 páginas. Nuclear, biological, and chemical overpressure filter system

Installation

Mount the wall flange over the air intake hole in the wall or ceiling.
Remove the red plastic shipping caps from the intake and output ports. The hand pump is only
installed when it is needed.
Install the intake hose — a slight twisting motion may help to seat it onto the intake port.
The hose couplings and hand pump are held in place by a shallow locking taper.
CAUTION
Only a slight force is needed to secure a tight connection, do not over tighten.
In order to keep the carbon in the adsorber from soaking up water vapor present in the atmosphere,
it is recommended to leave the red intake and output port shipping caps installed in the Safe Cell
when not in use. In the event of a nuclear, biological, or chemical event, removal of the shipping
caps and reconnecting of the hose only requires a few seconds.
AC electrical power
Connect the power cord to the control panel power socket and plug into an AC electrical outlet.
Switch on the lighted main power switch on the front control panel.
Automatic battery back up
Connect the 12 volt DC cable connector to the control panel socket and connect the clip leads
(jumper cable style clips) to a 12 volt DC deep cycle battery.
Ensure that the red positive clip lead is to the positive post of the battery (+).
CAUTION
User supplied
12 VDC deep cycle
battery
Optional emergency hand crank
Wall flange
120 VAC
outlet
Intake hose
Figure E-1
ASR-200-AV-NBC Safe Cell
Installation and Operation Manual
Revision C - April 27, 2016
Section
E
Page 7