Both a check valve and a shut-off
valve are recommended for each
pump. The check valve is used to
prevent backflow into the sump. The
shut-off valve is used to manually
stop system flow during pump
servicing.
Electrical Connections
Power cable:
The power cable mounted to the
pump must not be modified in any
way. This pump is provided with a 3
wire cord and 3 prong grounded
plug that must be connected into a 3
wire
grounded
Ground
receptacle. Do not bypass grounding
wires or remove ground prongs from
plug. This pump requires separate,
properly fused and grounded branch
circuit. Use of a ground fault circuit
interrupter
(GFCI)
recommended.
barmesapumps.com
The electrical outlet or panel shall be
within the length limitations of the
pump power cord, and at least 4 feet
above
floor
level
possible
hazards
conditions. Do Not use an extension
cord.
IF USED with Control Panel - Any
splice between the pump and the
control panel must be made in
accordance with the electric codes. It
is recommended that a junction box,
if used, be mounted outside the
sump or be of at a minimum NEMA 4
construction if located within the wet
well. DO NOT USE THE POWER
CABLE TO LIFT PUMP. Always rely
upon a Certified Electrician for
installation.
Overload Protection:
Single Phase - The stator in-winding
overload protector used is referred to
as an inherent overheating protector
and operates on the combined effect
of temperature and current.
This
means
protector will trip out and shut the
pump off if the windings become too
hot, or the load current passing
through them becomes too high.
IMPORTANT! - The overload will then
automatically reset and start the
pump up after the motor cools to a
safe temperature. In the event of an
overload, the source of this condition
should be determined and corrected
immediately.
WARNING
Fault
P U M P C Y C L E O R R U N I F A N
OVERLOAD CONDITION OCCURS.
If current through the temperature
sensor exceeds the values listed, an
is
strongly
intermediate control circuit relay
must be used to reduce the current
or the sensor will not work properly.
TEMPERATURE SENSOR ELECTRICAL
to
minimize
Volts
from
flood
110-120
220-240
Wire Size:
If longer power cable is required
consult a qualified electrician for
proper wire size.
Pre-Operation
1. Check Voltage and Phase -
Compare the voltage and phase
information stamped on the
pump name plate.
2. Check Pump Rotation - Improper
motor rotation can result in poor
pump performance and can
damage the motor and/or pump.
Incorrect rotation for Single-Phase
pumps is unlikely. If the rotation is
incorrect contact factory.
that
the
overload
D O N O T L E T T H E
RATINGS
Continuous
Inrush
Amperes
Amperes
3.00
30.0
1.50
15.0
Installation & Service
Plate
-
3. Name
information from the pump name
plate to drawing in front of
manual for future reference.
4. Insulation Test - An insulation
(megger)
test
performed on the motor. Before
the pump is put into service. The
resistance values (ohms) as well
as the voltage (volts) and current
(amps) should be recorded.
5. Pump-Down Test - Be sure pump
has been properly wired, lowered
into the basin, sump or lift station,
check the system by filling with
liquid and allowing the pump to
operate through its pumping
cycle. The time needed to empty
the system, or pump-down time
along with the volume of water,
should be recorded.
Maintenance
No lubrication or maintenance is
required.
Perform
the
checks when pump is removed from
operation
or
when
performance deteriorates:
a) Inspect motor chamber for oil
level and contamination.
b) Inspect impeller and body for
excessive build-up or clogging.
c) Inspect motor, bearings and shaft
seal for wear or leakage.
Servicing
Cooling Oil - Anytime the pump is
removed from operation, the cooling
oil in the motor housing should be
checked visually for oil level and
contamination.
To check oil, set unit upright. Remove
pipe plug from housing.
Record
the
should
be
following
pump