BOC BASELINE R104/1 Manual del usuario - Página 4

Navegue en línea o descargue pdf Manual del usuario para Controlador BOC BASELINE R104/1. BOC BASELINE R104/1 8 páginas. Cylinder and secondary pressure regulators

BOC BASELINE R104/1 Manual del usuario
4
BASELINE
cylinder and secondary pressure regulators
®
2.6 Particular danger from leakage
When using very hazardous, hazardous or slightly hazardous gases, danger to the operator and others can occur should a
malfunction or leak develop. Malfunctions of the pressure equipment or operation of relief valves and safeties can result in
the release of the hazardous gases into the work environment. When using hazardous gases take particular safety precau-
tions, including sufficient ventilation or evacuation. Securely Pipe away the exits of pressure relief and purge valves. Any
leaked materials are to be disposed of safely, in accordance with local regulations, and an environmentally friendly manner.
The operators are to be informed of the particular dangers of the gas they are using and of personal and other protection
measures necessary for the safe operation of pressure equipment.
2.7 Information on special types of gas
All parts that come into contact with oxygen must be completely free of oil, grease and particular matter, to avoid danger of
ignition and/or explosion! Where instructed to use a lubricant only use one with approval for oxygen service. When working
with acetylene, do not use tubing or other parts made of copper! Know and pay attention to the particular dangers of these
two and other reactive gases.
2.8 Design changes on the pressure control device
Without written permission from the manufacturer, no changes, extensions or redesign on the pressure control device or the
equipment are to be carried out.
2.9 Cleaning the gas device and disposal of the residue
Do not contaminate the equipment with oily rags or grease. Do not clean with solvents.

3. Storage, transport.

All pressure equipment must be clean and stored in a dust free, dry
and well-sealed environment. Do not use cleaning agents containing
solvents! Before returning pressure equipment to the manufacturer
it is absolutely necessary that all components be purged with inert
gas, if they have been in contact with corrosive or toxic gases.

4. Technical data.

4.1 Data sheets
All technical data can be seen on the product specific data sheets for
BASELINE
®
products. These are valid when used with the general op-
erating instructions. Specifically, the data sheets contain the maximum
intended inlet pressure, the working outlet range of the pressure device,
the external dimensions, the leak integrity or tightness, and the permis-
sible operating temperature range.
4.2 Pressure regulator series C106, C106X and R104
There are four R104 or six C106/C106X inlet and outlet ports with NPT
1/4" internal threads. Please always pay attention to the information
contained in the "Connections" and "Start-up" sections for all products.
4.3 Cylinder regulators C106/1, C106X/1 and C106/2, 106X/2
Cylinder regulators are designed to be connected directly to gas cylinders
to reduce cylinder pressure to a lower outlet pressure. The cylinder con-
nections have different threads depending on the type of gas used. Do
not use adapters or change cylinder connections.
4.4 Outlet valves
Cylinder regulators can be purchased with a type A multiple turn
Diaphragm positive shutoff valve, type B multiple turn needle valve,
or without an outlet valve. If a valve is installed, it is closed by turning
the knob in the anticlockwise direction and opened by turning it in the
clockwise direction.