Domus HRX-aQ AQH200-B Manual de instrucciones de instalación - Página 10

Navegue en línea o descargue pdf Manual de instrucciones de instalación para Ventilador Domus HRX-aQ AQH200-B. Domus HRX-aQ AQH200-B 12 páginas. Range mechanical ventilation with heat recovery

19.
Optional Duct Heater Operating Temperature Screen
7.11 Programming
From the home screen, press "PROG" (The programme number will
flash in the bottom left hand corner; P1 to P9).
Use the "+" and "-" buttons to view the selected programme
number (Factory default is P9).
The pre-programmed Thermal bypass programmes are shown in the
diagram (See Section XX).
Note: Each square has a time value of 30 minutes. Black squares
indicate a time period where the unit is in automatic bypass mode i.e.
the unit will monitor the temperatures and open or close the bypass
accordingly. White squares (blank spaces) indicate a time block where
the heat exchanger bypass will be permanently set to operate and
divert air around the heat exchanger regardless of the measured and set
temperatures.
Each of the programmes can be edited to create bespoke programmes
as follows:
From the home screen, press "PROG".
Use the "+" and "-" buttons to select the programme number
(Factory default is P9).
Press "PROG". The programme number will stop flashing and the
first block on the timeline at the bottom of the screen will begin to
flash.
Select the day to be edited by pressing "DAY" until the correct day is
displayed along the top of the screen (1 – Monday, 2 – Tuesday etc.).
To add a 30 minute temperature controlled bypass block (a black
square) to the timeline, ensure that the word "BYPASS" is displayed on
the screen by pressing "BYPASS".
Press the "+" and "-" buttons to move along the timeline at the
bottom of the screen; a block will be added to each position.
To remove a block, remove the word "BYPASS" from the screen by
pressing "BYPASS" and press the "+" and "-" buttons to move along
the timeline at the bottom of the screen; a block will be removed from
each position.
Daily 'timeline patterns' can be copied to another day or multiple
days to avoid programming each day individually.
From the home screen, press "COPY".
Select the day to copy by pressing "PROG" (the day number will
be displayed) and then the day to copy-to by pressing the "+" and "-"
buttons (the day number will flash). When the two correct days have
been selected, press "COPY" and the timeline pattern will copy across.
Press "SET" to record.
LAB1199R | OCTOBER 2023
7.12 Default Interface Factory Settings
P1
t3 - 20°C
t4 - 10°C
Humidity – 60%
Filter – 3000 hours
Fan 1 – Low 20%
Fan 1 – Boost 50%
Fan 1 – Max 80%
Fan 2 – Low 20%
Fan 2 – Boost 50%
Fan 2 – Max 80%
Bypass temp – off
T5
Delay-on – off
Delay-off – off
Hum - on

8.0 MAINTENANCE

The appliance G3/EU3 filters should be cleaned on a regular basis,
the exact frequency will be determined by individual living conditions,
but we recommend inspection every 3,000 hours (4 months) with
replacement every 27,000 hours (three years).
Before cleaning the filters, turn off the appliance at the isolator switch.
To remove the two filters, pull out the two caps from the front of the
appliance and gently slide out the filters in their carrier frames.
Lightly vacuum the filters to remove surface debris and then gently wash
through in warm soapy water. Ensure that the filters are completely dry
before refitting. Important: do not dry on a radiator or use excessive
heat as this will distort the carrier frames.
PAGE 10