American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205 Manual de instrucciones de instalación - Página 10
Navegue en línea o descargue pdf Manual de instrucciones de instalación para Mobiliario interior American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205. American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205 12 páginas. American standard selectronic innsbrook electronic lavatory faucet speciifcation sheet
También para American Standard Selectronic Innsbrook Electronic Lavatory Faucet 6057.205: Lista de piezas (1 páginas), Hoja de especificaciones (1 páginas)
FAQ'S
Q: How will I know if battery needs to be replaced?
A: Valve does not open and sensor blinks 2 times
interrupted by pause for up to 7 days.
Q: Why has the flow rate of the faucet reduced
significantly?
A: Check and clean aerator and strainer.
Q: There is no flow out of faucet when I'm in the
sensor range?
A: Check sensor. If sensor blinks 2 times interrupted
by pause, replace battery, or call 1800-442-1902.
Q: Why does the faucet operate the opposite of
expected-Turns On when not in sensor range, but
turns off when in sensor range?
A: Sensor wires to solenoid are reversed. Black to -
& Red to + is correct.
Q: What is the normal operating pressure range?
A: Faucet will operate with supply pressures ranging
from 20-80 psi.
9