Mounting Unit Using Wall Bracket
2.2 Option 1: Wall Mounting
The MVHR unit fixed to a solid wall construction using the
mounting bracket provided.
5
Ducting in the
ceiling void.
Side view of unit
mounted on the
block wall in a
cupboard.
397 Condensate
drain,
Uninsulated
drain pipe with
min 5° fall
running to SVP.
Typical Installation of Cupboard Mounted Unit Fixed to Blockwork Wall
2.3 Option 2: Wall Mounting
If it is not practical to use a solid wall, the MVHR unit should be
fixed to a stud partition with a 25mm minimum thickness MDF
panel solidly fixed behind the plasterboard.
If fixing to a stud wall the MDF panel should extend, width wise, over a
minimum of 3 vertical studs with centres of no more than 400mm. Add
additional vertical supports if necessary.
Height wise, ideally, the MDF panel should extend from floor to ceiling
but as a minimum should be a least 2m high.
Fix the mounting bracket to the wall (as figure 3) and use the wall
mounted bracket to mount the unit on (as shown in figure 4).
6
Ducting in the
ceiling void.
Side view of unit
mounted in a
cupboard fixed to
a stud partition
with the 25mm
MDF fixed behind
the plasterboard.
397 Condensate
drain,
Uninsulated
drain pipe with
min 5° fall
running to SVP.
Typical Installation of Cupboard Mounted Unit Fixed to Stud Partition
with MDF Reinforcement
LAB1355R | SEPTEMBER 2018
2.4 Option 3: Loft Space Mounting
The MVHR unit should be positioned on a tank stand using the
Anti-vibration tray assembly discarding the angle brackets.
Anti-vibration tray assembly is to be purchased separately (Part No.
HRXE-AV).
7
Valve in ceiling.
2.5 Option 4: Loft Space Mounting
The MVHR unit should be positioned on a 25mm minimum
thickness MDF panel that is vertically fixed across the roof trusses
to form a solid false wall.
Add additional vertical supports if necessary. Use the Anti-vibration tray
assembly including the angle brackets, to be purchased separately (Part
No. HRXE-AV).
8
Valve in ceiling.
Typical Installation of Loft Mounted Unit
Using Tray Assembly and Tank Stand
Typical Installation of Loft Mounted Unit Using Tray Assembly
PAGE 2