Electrical Wiring - Models 15, 19, 19L
1.
Install electrical hook up that applies to your unit. Make sure to
review your Electrical Installation Checklist and wiring diagram
(see Figure 3) for 120-volt switch, 220/240-volt switch, or DRC
low voltage control.
NOTE: Da-Lift projector lift has been internally wired at
Da-Lite. External wiring is completed by installer conforming
to local and national codes. Be sure the wires are long
enough for the Da-Lift to go up and down.
120V Wiring Diagram
120V.
Plug-In For T. V .
Figure 3
This Switch Cannot
Be Used With L. V .C.
240 Volt Wiring Diagram
Da-lite offers two styles of 240-volt wall switches for standard operation.
Please see wiring diagram included in wall switch box included with screen.
Up Limit
Switch N.C.
Opens When
Operated
Black (Hot)
White (Common)
White (Common)
120V.
Black (Hot)
Operating Switch,
Switch Box, And
Plate Furnished With
Da-Lift. (SPDT With
Center Off)
Red (Down)
Up
Off
Down
Side View Of
Switch & Box
2. Test installation by carefully running Da-Lift "up" and "down"
several times. Be prepared to stop the Da-Lift. Duty cycle is three
(3) minutes ON and three (3) minutes OFF.
3. Make sure Da-Lift stops in the up direction flush with the ceiling.
Junction
Box
Green
Black & Yellow
Black (Up)
AC Common
AC Hot
120V. AC 60Hz.
2.2 AMP. Max